PERFORMANCE TROUBLE SHOOTING

KONIFER WINDOW PERFORMANCE GUIDE

Maximizing Performance & Troubleshooting for PVC & Aluminum Window Systems

10 SMART STEPS TO MAXIMIZE WINDOW PERFORMANCE

Ensure Proper Installation
Windows must be installed plumb, level, and square in accordance with CSA A440 installation guidelines.
Improper installation is the leading cause of performance issues.
Inspect exterior and interior sealants regularly.
• Re-seal gaps immediately
• Ensure flashing and weather barriers remain intact
All Konifer window systems include drainage channels.
• Do not block weep holes
• Keep tracks clean from debris, dust, and ice
Use handles, locks, and hinges as intended.
• Avoid excessive force
• Ensure full locking engagement for proper sealing
Use non-abrasive cleaners only.
• Avoid harsh chemicals
• Do not use metal tools or abrasive pads
Condensation is often caused by indoor conditions.
• Maintain indoor humidity between 30–50%
• Ensure proper ventilation
Windows are not structural elements.
• Do not apply loads to frames
• Avoid attaching fixtures directly to window systems
During renovation or nearby work:
• Cover windows from dust, debris, and impact
• Avoid exposure to concrete, plaster, or chemicals
At least twice a year:
• Check seals, hardware, and alignment
• Inspect for visible damage
All adjustments or repairs should be carried out by:
• Qualified installers
• Authorized service personnel

TROUBLESHOOTING GUIDE

Condensation on Glass
Cause: High indoor humidity, temperature difference
Solution:
• Improve ventilation
• Reduce indoor humidity

Not a defect in the window system.
Cause: Sealant failure or improper installation
Solution:
• Inspect perimeter sealing
• Re-seal as required
Cause: Blocked drainage or improper flashing
Solution:
• Clear weep holes
• Verify exterior sealing
Cause: Misalignment or debris in track
Solution:
• Clean tracks
• Adjust hardware
Cause: Frame shift or misalignment
Solution:
• Adjust sash alignment
• Check installation tolerances
Cause: Loose hardware or pressure imbalance
Solution:
• Tighten fittings
• Ensure proper closure
Cause: IGU seal failure
Solution:
• Contact Konifer for inspection
• Replacement subject to warranty terms
Cause: Improper cleaning or impact
Solution:
• Prevent further damage
• Replacement only if required
Cause: Environmental exposure or cleaning agents
Solution:
• Clean using approved methods
• Avoid chemical cleaners
Cause: Building insulation or design limitations
Solution:
• Review wall insulation and envelope design

Window performance is dependent on overall building system.

⚠️ IMPORTANT DISCLAIMER

System Performance Disclaimer

KONIFER window systems are manufactured to meet applicable CSA and NAFS standards.

However, performance is dependent on:
• Proper installation
• Building envelope design
• Site conditions and maintenance

KONIFER shall not be responsible for issues arising from:
• Improper installation
• Environmental conditions
• Building deficiencies
• Third-party modifications

FINAL STATEMENT

PERFORMANCE IS A SYSTEM — NOT JUST A WINDOW Performance Statement

Optimal results are achieved when windows are properly installed, maintained, and integrated within the building envelope.

KONIFER
Engineered Window Systems — Built for Performance. Maintained for Longevity.