/

/

/

Structural Calculation

Structural Calculations

Engineered Performance. Verified Confidence.

At KONIFER , every window, curtain wall, storefront, and façade system is supported by rigorous structural analysis and engineering validation aligned with Canadian building requirements.

 

Our structural calculation approach ensures that all systems are designed to withstand wind loads, dead loads, live loads, and project-specific conditions, delivering long-term performance, safety, and compliance.

What We Provide

Konifer offers comprehensive structural calculation support for:

Each system is evaluated based on project-specific parameters, not generic assumptions.

Design Inputs & Engineering Considerations

Our structural calculations are based on detailed project inputs, including:

  • Building height and exposure conditions
  • Project location and regional wind load requirements
  • Span, mullion spacing, and glass dimensions
  • Dead load and live load conditions
  • Thermal movement and deflection limits
  • Structural anchoring and slab edge conditions
  • Seismic considerations (where applicable)

Because copying a standard detail into a 30-storey building is how failures happen.

Compliance with Canadian Standards

Konifer’s engineering approach aligns with applicable Canadian codes and standards, including:

All calculations are developed to meet design pressures, serviceability limits, and safety factors required for Canadian construction.

Structural Analysis Scope

Our engineering team provides:

Wind Load & Design Pressure Calculations

  • Determination of project-specific design pressures
  • Positive and negative pressure analysis
  • Zone-based façade pressure distribution

Mullion & Frame Structural Design

  • Aluminum profile selection based on load requirements
  • Deflection control (L/175, L/240 or project-specific criteria)
  • Reinforcement strategies where required

Glass Strength & Thickness Selection

  • Glass thickness based on wind load and panel size
  • Tempered, laminated, or insulated glass configurations
  • Compliance with safety glazing requirements

Anchorage & Connection Design

  • Anchor sizing and spacing
  • Load transfer to structure
  • Interface with slab edge and structural supports

System Deflection & Performance Control

Structural performance is not just about strength—it’s about movement control.

Konifer ensures:

  • Controlled deflection limits for frames and mullions
  • Glass edge protection and seal integrity
  • Compatibility with air, water, and thermal performance requirements

Because a system that “technically holds” but leaks or cracks is still a failure.

Engineering Deliverables

Depending on project scope, Konifer provides:

  • Structural calculation reports
  • Design pressure summaries
  • System-specific engineering analysis
  • Shop drawing support with structural validation
  • Coordination with consultants and engineers of record

Design Assist & Consultant Coordination

Konifer works closely with:

  • Architects
  • Façade consultants
  • Structural engineers
  • General contractors

We support projects from early design through execution, helping optimize system selection, reduce risk, and improve constructability.

Why Konifer

  • Strong understanding of Canadian wind and environmental conditions
  • Practical, buildable engineering solutions
  • Integration of structural + thermal + performance requirements
  • Experience across industrial, commercial, institutional, and residential projects
  • Reliable support from design to installation

Konifer delivers structurally engineered façade and window systems designed to meet real-world conditions—ensuring safety, performance, and long-term reliability across every project.